Input Voltage:
Input Frequency:
Input Current:
Load Range:
Ripple and Noise:
Line Regulation:
Load Regulation:
Hold Up Time:
Output Power:
Power Good:
Power Redundancy:
Efficiency:
Altitude:
Protection:
Temperature:
Humidity:
Connectors:
Dimensions:
MTBF: |
|
90~130VAC or 180~260VAC
47~63Hz
Not exceed 30A at 115VAC input or 60A AC input, at cold
start 25°C
When all outputs are in 60% rated load condition, the +5V output is
set between 4.98~5.02V while all other outputs are within the
specified voltage accuracy range
Peak to peak ripple and noise for +5V, output is < 50mV, and
< 100mV for +12V, -12V, -5V outputs at rated load, 115/230VAC
< +/-1% for each output at rated load and +/-10% of 115VAC or
230VAC input voltage change
The output voltage load regulation is less than the value on the
table when subjected to +/-40% change on each output load from
60% rated load, and while all other outputs are at 60% rated load
> 16ms at 115VAC input and rated load measured from the last AC
line charging pulse to the point when +5V drops to +4.75V
The total DC continuous power is whthin 230W at < 30°C ambient
temperature
When turned on, the signal goes high 100~500ms after all output
DC voltages are within regulation limits
This power supply has power redundant capability
> 70% at rated load
10,000 feet
Built-in over voltage protection circuit shuts down the outputs to
prevent damage. Trip point of crowbar circuit is between 5.7~7V;
latch off mode against short circuit or over load conditions AC line
ON/OFF cycle recovers unit from fault conditions
Operating: 0~40°C
Storage: -40~+75°C
Operating: 5~95%; non-condensing at 40°C
AC: One AC input socket
DC: O1 DIN 41612 C96
14.0 x 15.0 x 8.62 cm +/-5mm tolerance
235,743 hrs. |
|