Input Voltage:
Input Frequency:
Input Current:
Inrush Current:
Switching Frequency:
Brown Out Voltage:
Output Power:
Power Up Time:
Power Good:
Power Fail:
Efficiency:
Altitude:
Protection:
Thermal System:
Temperature Coefficient:
Temperature:
Humidity:
Dimensions:
|
|
90~135VAC, nominal 115VAC (90V at 200W, 103V at 250W
load) or 180~265VAC, nominal 230VAC; selectable by side
switch
47~63Hz single phase
6A (RMS) for 115VAC at without AC outlet; 3A (RMS) for
230VAC
70A at cold start
30KHz typical
95V~max. 60Hz
250W at 45°C
< 20ms for +5V output voltage
The power good signal will not be higher than 100~500ms
after the +5V output stabilizes at its operating value when the
unit is turn on
The TTL compatible signal will go down at least 1ms before
+5V below 4.75V
80% min. at full load (AC input 230V)
10,000 feet
Over Voltage: 5.5~6.9V for +5V output, 13.8~15.6V for +12V
output
Over Load: Total output from 110% min. to 140% max.; all
output equipped w/short circuit protection; the outputs shall
shut down if shorted to zero volts output
Forced air ventilation by DC ball bearing cooling fan; fan
status monitoring is optional
+0.05% per°C
Operating: 0~50°C
Storage: -10~+70°C
Operating: 20~90% RH
Storage: 10~98% RH
15.0 x 14.0 x 8.6 cm |
|