Input Voltage:
Input Current:
Inrush Current:
Load Range:
Ripple and Noise:
Line Regulation:
Load Regulation:
Efficiency:
Altitude:
Protection:
Temperature:
Connectors:
Dimensions: |
|
36~72VDC
5A at 48VDC max.
< 10A at 48VDC input from a cold start 25°C excluding EMI
suppression capactiors
With all other outputs within their accuracy ranges and all output
at 60% rated load, the +5V output is between 4.95~5.05V. Max.
load can not exceed 80W convection cooling and 100W forced
air cooling
Peak to peak ripple and noise for +5V is < 50mV, and < 100mV
for the other outputs at rated load, nominal line
< +/-1% for each output at rated load and +/-10% of input voltage variables
< +/-1% for +5V, and < +/-5% for -12V, +12V, -5V while changing measured output load from +/-40% to 60% rated load and keeping other outputs at 60% rated load
> 70% at DC24V and rated load
10,000 feet
Built-in over voltage protection circuit. Trip point of crowbar circuit
is between 5.7~7V. Hiccup mode against short circuit or over load
conditions auto recovery when fault conditions are removed
Operating: 0~50°C
Storage: -40~+85°C
DC Input: Terminal blocks
DC Output: Terminal blocks
15.24 x 8.38 x 3.8 cm with +/-0.8mm and +/-0.4mm tolerance
between mounting holes |
|