Input Voltage:
Input Frequency:
Input Current:
Inrush Current:
Load Range:
Ripple and Noise:
Line Regulation:
Load Regulation:
Hold Up Time:
Power ON/OFF:
Efficiency:
Altitude:
Protection:
Temperature:
Connectors:
Dimensions: |
|
85~264VAC
47~63Hz
3A at 115VAC or 1.5A at 230VAC max.
< 30A at 115VAC input or < 60A at 230VAC input at 25°C cold start
With the +5V output set between 5.08~5.13V and all output at
60% raged load, while the other outputs are withing the
accuracy range; max. total combined output power on the 3.3V
and 5V rails is 70W, with the max. load not exceeding 120W
Peak to peak ripple and noise is < 50mV for +5V and 3.3V
outputs, 120mV for +5Vsb, < 120mV for +12V, and 200mV for
-12V at rated load and nominal input
< +/-1% for rated load with a +/-10% change in input voltage
< +/-2% for +5V, < +7~-3% for +12V, < +8~-3% for -12V,
< +/-5% for +3.3V with measured output load changing within
+/-40% and 60% rated load, while keeping other outputs at
60% rated load
> 16ms at 115VAC input and rated load
Turns on power supply when power on/off pin is connected to
secondary GND
> 70% at nominal line and rated load
10,000 feet
Hiccup mode against short circuit or over load conditions auto
recovery when fault conditions are removed
Operating: 0~50°C; output power is 100W with 6CFM forced air, 120W with 18CFM forced air
Storage: -40~+85°C
AC Input: Molex 5273-05A withdraw 2-pin or equivalent device
DC Output: TB2 is Molex 5273-14A or equivalent device;
TB3 is Molex 5045-03A or equivalent device
8.38 x 15.24 x 3.97 cm. Tolerance at +/-0.4mm |
|