Input Voltage:
Input Current:
Inrush Current:
Load Range:
Ripple and Noise:
Line Regulation:
Load Regulation:
Hold Up Time:
Power On/Off:
Power Good Signal:
Power Fail Signal:
Efficiency:
Altitude:
Protection:
Temperature:
Humidity:
Connectors:
Dimensions: |
|
The range of input voltage is from 10~30VDC, nominal input voltage is 12 and 24VDC
18A at 10VDC max.
Less than 30A at 10VDC input
At the factory, the +5V output is set between 5.08~5.13V and all output at 60% rated load; the other outputs are checked to be within the accuracy range. The maximum total combined output power on the +3.3V and +5V rails is 70W. The max. load cannot exceed 120W
The peak to peak ripple and noise for +5V, +3.3V output are less than 100mV for +5V sb is 120mV, for +12V is less than 120mV, for -12V is less than 200mV at ranted load and nominal input, with is measured by a 20MHz bandwidth limited oscilloscope and the each output is connected with a 0.47uF capacitor
Less than +/-2.5% at rated load with +/-10% change in input voltage
+5V is less than +/-2%, for +12V is less than +/-5%, for -12V +/-5%, +3.3V is less than +/-5% while the measuring is done by changing the measured output loading +/-40% from 60% rated load, and keep other output is at 60% rated load
The hold up time is longer than 16mS at 115VAC input
and rated load
The power supply will start-up when the power on/off pin be connected to secondary GND
The power is turned on, the power good signal will go high between 100ms to 500ms after all output DC voltage are within regulation limits
The power fail signal will go low at least 1ms before any of the output voltages fall below the regulation limits
> 70% while measuring at nominal line and rated load
0~10,000 feet
The power supply will generate the hiccup mode to protect itself against short circuit or over load condition, and will return to normal after wrong condition is removed
When the power supply operating over the temperature limit, the
Operating: 0~50°C, output power is 120W forced air cooling, 85W convection cooling
Storage: -20~+70°C
10~90%, non-condensing
DC Input (CN1): Dinkle DT-35-B01W-03 or equivalent
DC Output (CN2): Molex 5273-14A or equivalent
DC Output (CN3): Molex 5045-03A or equivalent
Power Good Output (CN4): Molex 5045-02A or equivalent
Fan Output (CN5): Molex 5045-02A or equivalent
15.24 x 8.38 x 3.8 cm with +/-0.4mm tolerance |
|