Input Voltage:
Input Frequency:
Input Current:
Inrush Current:
Load Range:
Ripple and Noise:
Line Regulation:
Load Regulation:
Efficiency:
Altitude:
Protection:
Temperature:
Connectors:
Dimensions: |
|
10~30VDC with normal line at +24VDC
47~63Hz
13A at 10VDC max.
< 15A at 10VDC input from cold start excluding EMI capactiors
With all other outputs within their specified voltage accuracy
ranges and 60% rated load conditions, the +5V output is between
5~5.1V. It could last 10 sec. at peak load and 25°C
Peak to peak ripple and noise for +5V is < 50mV, and < 100mV
for the other
< +/-2% for each output at rated load and < +/-10% +12V and
+24V input variables
< +/-1% for +5V, < +/-5% for +12V and -12V
> 70% at nominal line and rated load
10,000 feet
Built-in over voltage protection circuit. Trip point of crowbar circuit
is between 5.7~7V hiccup mode against short circuit or over load
conditions auto recovery when fault conditions are removed
O.C.P. of +5V is 20A max.
Operating: 0~50°C
Storage: -40~+85°C
DC Input: Terminal blocks
DC Output: Molex 5273-04A or equivalent device
For Fan Use Only: Molex 5045-02A or equivalent device
12.7 x 7.62 x 3.86 cm at tolerance +/-0.4mm |
|