Input Voltage: Input Frequency: Input Current:
Load Range:
Ripple and Noise:
Line Regulation: Load Regulation:
Hold Up Time:
Output Power:
Power Good: Power Fail: Efficiency: Altitude: Protection:
Temperature:
Humidity: Connectors:
Dimensions:
MTBF: |
|
90~265VAC 47~63Hz Not exceed 30A at 115VAC input or 60A AC input, at cold start 25°C When all outputs are at 60% rated load condition, the +5V output is set between 4.90~5.10V and all other outputs are within the specified voltage accuracy range Peak to peak ripple and noise for each output is < 1% of each output voltage at rated load 115~230VAC < +/-1% at rated load with +/-10% change in input voltage The output voltage load regulation is less than the values on the table when each output loading changes +/-40% from 60% rated load while all other outputs at 60% rated load 14ms typ. from the last AC line charging pulse to the point when +5V drops down to +4.75V Total DC continuous power is whthin 200W at 40°C ambient temperature. If the input voltage is < 100VAC, total DC continuous power should not exceed 180W Goes high 100~500ms after all DC output are ready Goes low 1ms before any DC output falls > 65% at nominal line and rated load 10,000 feet Built-in crowbar circuit automatically shuts down outputs to avoid damaging external circuits. Trip point of O.V.P. circuit is between 5.7~7.0V Operating: 0~70°C Storage: -40~+75°C Operating: 5~95%; non-condensing at 40°C AC Input/Output: Meets IEC 320/CEE 22 standard Tab Terminals: Female 0.250" x 0.032" CPU Board: Alex 8500-06 or equivalent device 3.5" Disk Drive: AMP 1-480424-0/171822-4 or equivalent device 14.0 x 15.0 x 8.62 cm with +/-0.8mm and +/-0.4mm tolerance between mounting holes 156,598 hrs. |
|