Input Voltage: |
The range of input voltage is from 90~264VAC |
Input Frequency: |
47~63Hz |
Input Current: |
The maximum input current is 0.65A at 115VAC or 0.32A at 230VAC |
Inrush Current: |
The cold inrush current will limit less than 50A at 264VAC input voltage |
Ripple and Noise: |
Measuring is done by 20MHz bandwidth limited oscilloscope and terminated each output with a 0.1uF ceramic capacitor and a 10uF electrolysis capacitor at rated load, nominal line |
Line Reguration: |
The line regulation is less than +/-0.5% while measuring at rated load and from 100VAC to 240VAC input voltage changing |
Load reguration: |
The load reguration for output is less than +/-1%, measuring is done by changing the output load +/-40% from 60% rated load |
Hold Up Time: |
Hold up time is 8mS typical at 115VAC, full load |
Protection: |
The power supply will go into hiccup mode against short circuit or over load conditions, and will do auto-recovery while faulty conditions are removed |
Temperature: |
0~+50°C (operating); -40~+85°C (storage) |
Humidity: |
5~95% non-condensing |
Connectors: |
I/P Connector: Molex housing 09-50-3031 and Molex 2878 series crimp terminal O/P Connector: Molex housing 09-50-3041 and Molex 2878 series crimp terminal |
Dimensions: |
10.16 x 5.08 x 3.048 cm; tolerance specified is +/-0.4mm |