Input Voltage: Input Current: Inrush Current:
Load Range:
Ripple and Noise:
Line Regulation:
Load Regulation:
Hold Up Time:
Efficiency: Altitude: Protection:
Temperature:
Connectors:
Dimensions: |
|
85~270VAC 2A at 115VAC or 1A at 230VAC max. Not exceed 30A at 115VAC input or 60A at 230VAC input, at cold start 25°C, and excluding EMI suppression capactiors All outputs are at min. load conditions, while +5V output is between 5~5.1V and all other outputs are within the specified voltage accuracy range Peak to peak ripple and noise for all outputs is < 1% of output voltage at rated load < +/-2% for each output measured at rated load and +/-10% input voltage range < +/-3% for +5V, +/-4% for +12V, and +/-5% for -12V with +/-40% change on the measured output load, +/-40% from 60% rated load, while keeping other outputs at 60% rated load > 16ms at 115VAC input and rated load, measured from the end of the last charging pulse to when the main output drops down to 95% output voltage > 70% at nominal line and rated load 10,000 feet Latch-off mode against short circuit or over load conditions AC input ON/OFF cycle to restart power supply Operating: 0~50°C Storage: -40~+85°C AC Input: Molex 5277-02A or equivalent device DC Output: Molex 5273-08A or equivalent device For Fan Use Only: Molex 5045-02A or equivalent device 12.7 x 7.62 x 3.86 cm at tolerance +/-0.4mm |