Input Voltage: Input Frequency: Input Current: Inrush Current:
Load Range:
Ripple and Noise:
Line Regulation: Load Regulation:
Hold Up Time: Efficiency: Altitude: Protection:
Temperature:
Humidity: Dimensions: MTBF: |
|
85~264VAC 47~63Hz 3A at 115VAC or 1.5A at 230VAC max. capacitors Not exceed 30A at 115VAC input or 60A at 230VAC input, cold start at 25°C t With +5V output set between 4.95~5.05V and all output at 60% rated load, and all other outputs in the accuracy range, max. load can not > 80W convection cooling and > 100W forced air cooling Peak to peak ripple and noise for each output is < 1% of each output voltage at rated load < +/-1% at rated load with +/-10% change in input voltage < +/-1% for +5V, < +/-5% for other outputs with +/-40% change in measured output loading from 60% rated load and other outputs at 60% rated laod > 16ms at 115VAC input and rated load > 70% at nominal line and rated load 10,000 feet Short Circuit: Hiccup mode against short circuit or over load conditions auto recovery to normal after wrong conditions are removed Output: Built-in crowbar circuit shuts down outputs to avoid damage. Trip point of over voltage protection is between 5.7~7.0V AC line ON/OFF restarts and recovers the unit from over voltage protection 0~50°C, requires forces air of 30CFM for outputs > 80W (operating); -20~+70°C (storage) 5~95%; non-condensing at 40°C (operating) 15.24 x 8.38 x 3.8 cm within +/-0.4mm tolerance 283,179 hrs. |
|