Input Voltage: Input Frequency: Input Current: Inrush Current:
Load Range:
Ripple and Noise:
Line Regulation: Load Regulation: Hold Up Time: Efficiency: Altitude: Protection:
Temperature:
Connectors:
Dimensions: |
|
85~264VAC 47~63Hz 3A at 115VAC or 1.5A at 230VAC < 30A at 115VAC input or < 60A at 230VAC input, under 24°C cold start With all output at 60% rated load, +5V is between 4.95V and 5.05V. All other outputs are within the accuracy range. Effective so long as the max. load does not exceed 90W continuous convection cooling Peak to peak ripple and noise for each output is < 1% of each output's voltage at rated load < +/-1% for rated load with +/-10% change in input voltage < +/-1% for +5V and < +/-5% for all other outputs > 16ms at 115VAC input and rated load > 70% measured at nominal line and rated load 10,000 feet Built-in crowbar circuit. Trip point is between 5.7~7V. AC line off and on cycle for over voltage recovery and restart hiccup mode protection against short circuit or over load condition Operating: 0~50°C forced air 30CFM needed when output > 80W Storage: -40~+85°C AC Input: Molex 5273-05A withdraw 2-pin or equivalent device DC Output: Molex 5273-12A or equivalent device 7.0 x 20.0 x 3.8 cm at tolerance +/-0.4mm |
|