Input Voltage: Input Current: Inrush Current:
Load Range:
Ripple and Noise:
Line Regulation:
Load Regulation:
Efficiency: Altitude: Protection:
Temperature:
Connectors:
Dimensions: |
|
18~36VDC 7A at 24VDC max. < 10A at 24VDC input from a cold start 25°C excluding EMI suppression capactiors With all other outputs within their accuracy ranges and all output at 60% rated load, the +5V output is between 4.95~5.05V. Max. load can not exceed 80W convection cooling and 100W forced air cooling Peak to peak ripple and noise for +5V is < 50mV, and < 100mV for the other outputs at rated load, nominal line < +/-1% for each output at rated load and +/-10% of input voltage variables < +/-1% for +5V, and < +/-5% for -12V, +12V, -5V while changing measured output load from +/-40% to 60% rated load and keeping other outputs at 60% rated load > 70% at DC24V and rated load 10,000 feet Built-in over voltage protection circuit. Trip point of crowbar circuit is between 5.7~7V. Hiccup mode against short circuit or over load conditions auto recovery when fault conditions are removed Operating: 0~50°C, can start up -20°C Storage: -40~+85°C DC Input: Terminal blocks DC Output: Molex 5273-12A 15.24 x 8.38 x 3.8 cm with +/-0.8mm and +/-0.4mm tolerance between mounting holes |
|