Input Voltage: Input Current: Inrush Current: Ripple And Noise:
Line Regulation:
Load Regulation:
Output Power:
Efficiency: Altitude: Protection:
Temperature:
Connectors:
Dimensions: MTBF: |
|
19~32VDC Max. 20A at 24VDC < 5A at 24VDC input, cold start at 25°C Peak to peak ripple and noise is < 50mV for +5V and +3.3V outputs, < 100mV for other outputs when output voltage is at rated load < +/-1% for each output measured at rated load and +19~+32V input voltage variables Output voltage load regulation is less than the value on the table when each output load changes rated loads from +/-40%~60%, with all other outputs at 60% rated load Total DC continuous power is within 300W at < 30°C ambient temperature and 24~32V input voltage; max. total combined output power on 3.3V and 5V rails is 150W 65% typical at nominal line and rated load 10,000 feet Input: Protection against wrong polarity when 24VDC input is inversely connected by mistake Output: Built-in over voltage protection circuit. Trip point of crowbar circuit is between 5.9~7.0V. Hiccup mode against short circuit or over load conditions auto recovery when faulty conditions are removed Operating: 0~70°C Storage: -40~+75°C Input: Three positions terminal block DC Output: Output provides one AT type P8/P9 and two disk drive connector 14.0 x 15.0 x 8.62 cm with +/-0.8mm and +/-0.4mm tolerance 116,858 hrs. |